Boxerly Veterinary ultrasound Equipment

Industry News

Four important parameters in the design of high-voltage pulse modulation in veterinary B-ultrasound systems

Views :
Update time : 2024-09-03 14:44:29

The circuit design of the veterinary B-ultrasound system includes high-voltage pulse modulation circuit and high-speed array selection switch circuit. The following four important parameters are mainly considered in the design process of high-voltage pulse modulation.

The main important parameter to be considered in the design process of high-voltage pulse modulation is the excitation pulse amplitude of the veterinary B-ultrasound system transducer: This parameter refers to the maximum amplitude of the signal loaded on the transducer chip. This amplitude determines the intensity of the ultrasonic energy emitted by the transducer. At the same frequency, the higher the amplitude, the stronger the energy of the ultrasonic wave emitted. The amplitude of the excitation pulse of the veterinary B-ultrasound system transducer is determined by the external excitation power supply and the driver.

The main important parameter to be considered in the design process of high-voltage pulse modulation is the response time of the veterinary B-ultrasound system driver: In the veterinary B-ultrasound probe drive circuit, mosfet is mostly used for driving, including push-pull drive and H-bridge drive. The response time of the mosfet driver used in this system directly determines the quality of the ultrasonic signal. For ultrasonic waves with a transmission frequency of 1MHZ-15MHZ, the rise time and fall time of the mosfet should be within 15ns respectively.


The driving capability of the important parameters is mainly considered in the design process of high-voltage pulse modulation: the driving capability of mosfet is also the key to selecting mosfet, including the maximum driving voltage and driving current. As a digital ultrasonic transmitting system, the driving voltage of n-mos is not less than 1OOV, the driving voltage of p-mos is not less than -100V, and the driving current is not less than 2A.

The transmission frequency of the important parameters is mainly considered in the design process of high-voltage pulse modulation: the transmission frequency of the veterinary B-ultrasound system probe is mainly determined by the transmission controller and the matching network. When the transmission frequency is equivalent to the center frequency of the veterinary B-ultrasound system probe chip, the matching network resonates to produce the maximum transmission power. Of course, as a detection need, different transmission frequencies have better detection effects for different detection objects. When a broadband probe is used, the best ultrasonic detection is achieved through frequency conversion technology.



link: https://www.bxlimage.com/nw/286.html

tags: veterinary B-ultrasound B-ultrasound
Related News
Using B-ultrasound to observe changes in the ovaries of ewes
Using B-ultrasound to observe changes in the ovaries of ewes
09-26-2024
Observation of ovaries after delivery of ewes. In the early postpartum period, t...
The reserve dairy cows that have passed the B-ultrasound examination
The reserve dairy cows that have passed the B-ultrasound examination
09-26-2024
From birth to breeding and mating, calves go through three periods: neonatal per...
Animal B-ultrasound assisted ovulation monitoring in female dogs
Animal B-ultrasound assisted ovulation monitoring in female dogs
09-26-2024
Animal B-ultrasound diagnostic technology can be used to identify ovulation in f...
Veterinary B-ultrasound measurement of back fat, eye muscles, and intramuscular fat
Veterinary B-ultrasound measurement of back fat, eye muscles, and intramuscular fat
09-26-2024
When using veterinary B-ultrasound to measure the back fat and eye muscle area o...
Animal B-ultrasound 加热伸缩率试验仪 cows veterinary ultr 百格刮擦仪