Veterinary B-ultrasound Equipment

Industry News

The process of using ultrasound to examine the gallbladder and kidneys of cows

Views :
Update time : 2024-09-11 17:35:10

The gallbladder of cows, as an important organ of the digestive system, is embedded in the gap between the liver and the abdominal wall. When cows use B-ultrasound to explore the liver, the morphology and structural characteristics of the gallbladder can be clearly seen. The gallbladder shape is pear shaped, with a narrow and round head and a wide and blunt tail. The gallbladder wall shows moderate echogenicity, and the boundary is clear and neat. When cows use a B-ultrasound probe placed on the head side of the gallbladder, the bile duct can be observed through changes in respiratory status. The bile duct is the same as the gallbladder wall, and the boundary is clear and easy to see.

The acquisition coefficient of normal cow kidney ultrasound images:

The process of using ultrasound to examine the gallbladder and kidneys of cows(图1)

Type of B-ultrasound probe for cattle: convex array transducer probe; Probe frequency: 3-4.5MHz; Depth: 16-22cm; Dynamic range: 80-90dB;

Time gain compensation: centered; Total gain: 80-100dB; Spread speed: TI=1.2; Focus position: 6-8cm;

Operation site: The 12th intercostal space on the left and right sides of the body, as well as the 13th rib arch and the posterior extension of the rib fossa, are used to obtain the best bovine ultrasound images of the kidney in different intercostal spaces.

The 12th intercostal space and the posterior edge of the 13th rib on the dorsal side of the right abdominal wall of cows can be detected by a bovine B-ultrasound probe to detect the right kidney, while the left kidney is difficult to detect through the body surface. The cow kidney as a whole presents an irregular multi nipple shape. When the bovine B-ultrasound probe is used vertically to the body surface, an elliptical structure can be observed in the renal pelvis section. The renal medulla shows weak echo intensity and homogeneous light spots. The echo intensity of the bovine renal cortex is slightly lower than that of the liver, and the light spots are thinner and denser in the bovine B-ultrasound image. The cow renal sinus is high echo.



link: https://www.bxlimage.com/nw/550.html

tags: bovine ultrasound
Related News
Ultrasound characteristics of pregnant cows detected by B-ultrasound at different days
Ultrasound characteristics of pregnant cows detected by B-ultrasound at different days
09-14-2024
Around the 31st day of pregnancy in cows, the length of the forelimbs and hindli...
Three benefits of using portable bovine ultrasound machines in dairy farms
Three benefits of using portable bovine ultrasound machines in dairy farms
09-14-2024
Cow practitioners widely adopt and use bovine ultrasound machines for routine re...
Monitoring the technique of frozen semen insemination in cows using B-ultrasound
Monitoring the technique of frozen semen insemination in cows using B-ultrasound
09-12-2024
Before the cow is fertilized, the breeder's fingernails should be cut short ...
Using B-ultrasound to improve the reproductive rate of imported cows
Using B-ultrasound to improve the reproductive rate of imported cows
09-11-2024
Reproduction is one of the main functions of dairy cows and a key link in their ...
Animal B-ultrasound